Filter Results By:

Products

Applications

Manufacturers

DC Power Supplies

Convert and provide Direct Current (DC) power to a device or group of devices.

See Also: Bipolar Power


Showing results: 646 - 660 of 798 items found.

  • Inclinometer Systems

    Columbia Research Laboratories

    Columbia Research Labs offers our standard Inclinometer System and our Differential Inclinometer System. The standard system includes a temperature compensated force balance inclinometer in conjunction with a power module and convenient digital display. It is available with either AC or DC Power supply input. The Differential System allows the customer to match the slope of two remotely located surfaces. The readout can be set to indicate the absolute tilt of either sensor or the differential angle between them.

  • High Power DC Power Supply

    Maynuo Electronic Co.,Ltd

    *Low ripple and low noise*High resolution and accuracy (0.1mV/0.01mA)*Built-in high-accuracy 5 1/2 voltmeter and milliohmmeter*Supporting high-accuracy and dynamic programming output*High-luminance VFD screen with two lines& four channels display*Intellegent fan system fan will be automatically initiated according to the temperature*Supporting remote voltage compensation and multidata storage*Supporting external trigger input and output*Power-on-self-test, software calibration and standard rack mount*Using standard SCPI protocol*Communication mode: RS232/RS485/USB.

  • Low Voltage DC / Battery Powered High Voltage Amplifiers

    WMA-005 And WMA-005LF - Falco Systems

    The Falco Systems WMA-005 is a high voltage amplifier that runs from an 24 - 30V DC power supply and can be battery powered if required, e.g. for use in a Faraday cage. Its internal high voltage generator is inductor-free and hence does not spread magnetic interference in sensitive experimental setups. The output noise is impressively low at 3mVrms. For extremely low noise applications where bandwidth is not an issue, a dedicated WMA-005LF version is available that contains an output low pass filter capacitor which reduces the bandwidth to 50Hz, but makes the noise drop to below 0.1mVrms. This bandwidth-limited amplifier is ideal for MEMS or piezo positioning with manual voltage adjustment.

  • Low Voltage DC / Battery Powered HV Amplifiers

    WMA-01 And WMA-01LF - Falco Systems

    The Falco Systems WMA-01 is a high voltage amplifier that runs from an 24 - 30V DC power supply and can be battery powered if required, e.g. for use in a Faraday cage. Its internal high voltage generator is inductor-free and hence does not spread magnetic interference in sensitive experimental setups. The output noise is impressively low at 3mVrms. For extremely low noise applications where bandwidth is not an issue, a dedicated WMA-01LF version is available that contains an output low pass filter capacitor which reduces the bandwidth to 50Hz, but makes the noise drop to below 0.1mVrms. This bandwidth-limited amplifier is ideal for MEMS or piezo positioning with manual voltage adjustment.

  • Low Voltage DC / Battery Powered HV Amplifiers

    WMA-02 And WMA-02LF - Falco Systems

    The Falco Systems WMA-02 is a high voltage amplifier that runs from an 24 - 30V DC power supply and can be battery powered if required, e.g. for use in a Faraday cage. Its internal high voltage generator is inductor-free and hence does not spread magnetic interference in sensitive experimental setups. The output noise is impressively low at 4mVrms. For extremely low noise applications where bandwidth is not an issue, a dedicated WMA-02LF version is available that contains an output low pass filter capacitor which reduces the bandwidth to 50Hz, but makes the noise drop to below 0.2mVrms. This bandwidth-limited amplifier is ideal for MEMS or piezo positioning with manual voltage adjustment.

  • High-accuracy Multi-channel Programmable DC Power Supply

    N39400 Series - Next Generation Instrumental (Shanghai) T&C Tech. Co., Ltd.

    N39400 series is a high-accuracy & multi-channel programmable DC power supply with standard 19-inch 2U design, available for cabinet installation. Single N39400 supports Max. 4 channels output, with channels isolated. Both local operation on front panel and remote control on a computer are supported. N39400 can be widely used in lab test, system integration test, production aging line, etc.

  • Loop-Powered Transmitters and Drivers

    4-20mA - Riverhawk Company

    Loop-Powered Transmitters convert the output from proximity probes, seismic sensors, into a 4-20mA DC current, which is proportional to the input being measured. The transmitter converts the displacement or vibration signal to DC voltage and/or current for a DCS or PLC system. They control a 4-20mA current loop for a specified vibration range (ex. 0-5 mils peak-to-peak). The transmitters have a two-wire hook-up, powered solely by the loop current and have a power supply range of 15 to 36 volts.

  • DC Voltage Test System

    HIGHVOLT Prüftechnik Dresden GmbH

    DC test systems are used to test components and complete systems found in electrical power supply systems and operating on DC voltage.

  • Low-Light-Level Detection Modules

    Excelitas Technologies Corp.

    From single photons to mW, from 400nm to 1.7µm, the Excelitas family of Low-Light-Level Detection (L3D) Modules offers industry-leading performance in compact, easy-to-use packages operating from a single 5V DC power supply.

  • VirtualBench All-in-One Instrument

    NI

    The VirtualBench All-in-One Instrument combines a mixed-signal oscilloscope with protocol analysis, an arbitrary waveform generator, a digital multimeter, a programmable DC power supply, and digital I/O. The all-in-one features are simple, convenient, and provide more efficient circuit design, debugging, and validation. The included software lets you view all measurements on a single screen and can be updated with free software releases to add functionality and value. The VirtualBench All-in-One Instrument easily integrates with LabVIEW software to provide programmatic control and automated test sequences.

  • Natural Cooling Input 380VAC 3 Phase to Output 190-300VDC 10A-40A Rectifier Battery Charger

    SD230D20ZZ - Zhejiang Sandi Electric Co., Ltd

    SANDI “SD” series intelligent high-frequency switch power supply modules are specially developed to meet the demands of modern DC system. The charger rectifiers are designed with world leading patent technology “resonant voltage type soft switching power supply technology”. They feature high efficiency and stability, intelligent control, small size and light weight. Standard RS-485 interface, easy to connect with automation system. “Four remotes” functions, intelligent management. The products are widely used in power plant, substations and etc..Main characteristic of the moduleModularization design, realize N+1 backup;The friendly man-machine interface. Large screen to show, realize man-machine dialogue operate really.RS-485 inrerface, realize “4 remote” function with monitor machine.High efficiency, Nearly 95%-96%;Lightly, 230V/10A natural cooling module only 9kg;Little volume, 230V/10A natural cooling module dimension only 325mm×230mm×130mm;After the full bridge rectifying circuit rectifies 3-phase AC to DC, then adjusted by reactive PFC, power factor>0.94;Function against reverse pour: each module has been added diode against reverse pour at output terminal.LED digital screen, digital calibrate, stable current ,fault alarm Main characteristic of the ModulesThe friendly man-machine interface. LED digital screen, digital calibrate, stable current ,fault alarmHigh efficiency, up to 95%-96%;Light weight, Small sizeAfter the full bridge rectifying circuit rectifies 3-phase AC to DC, then adjusted by reactive PFC, power factor>0.94;Unequal current ratio of parallel connection<+/-3%, can ensure twenty modules work well by parallel connection.Multiple protections including over/under voltage, current limiting, short-circuit, parallel protection, over-temperature protection.Output over-voltage protectionTo prevent the disastrous accident caused by output overvoltage, there is overvoltage protection circuit in the module. Once the output voltage is higher than the threshold, the module locks up automatically and fault indication light is on, the faulty module quits work automatically and doesn’t affect the normal operation of the entire system.Output current limiting protectThe output current cannot increase infinitely. The maximum value of the output current of each module is limited to the rated output current 105%, in this range, the output current value of the module is continuously adjustable. If the load output of the module, the module will play down the output voltage.Output short-circuit protectionWhen short circuit, the output voltage drops to 0 immediately. Limit the short circuit current under 15% of rated output current. The module will not be damaged under short circuit state for a time, and resumes to work automatically after debugging. Module parallel protectionThere is parallel protection circuit in each module to ensure that when the fault module quits the system, the normal work of other modules and the system won’t be effect.Output over-current protectionThe output current cannot increase infinitely. If overloaded, the output voltage decreases automatically to protect the power components. The over current protection can be resumed automatically.

  • Scienlab Dynamic DC Emulator

    SL104XA Series - Keysight Technologies

    The Scienlab Dynamic DC Emulator provides an all-in-one system for efficient and effective testing of the power electronic components in electric vehicles (EV) and electric vehicle supply equipment (EVSE).

  • Fully Automatic Transformer Winding Resistance Tester

    Neutronics Manufacturing Co.

    Measure DC resistance of transformers windings etc. Introduction: The NMC ''TDR'' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. ''TDR'' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. ''TDR'' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.Principle: The constant current generated is fed to the resistance under test through the current terminals and the voltage drop across the resistance under test is measured and displayed in ohms. A true four terminal measurement is used to eliminate the need for lead resistance compensation.

  • Speed ​​Limiter Tester

    SLT 1 - Maschinenbau Haldenwang GmbH & Co. KG.

    Mobile handheld device with illuminated display and keypad for K-value determination and speed limiter function testConnector for multi-function plug (incl.)Adapter cable for VDO Kienzle tachograph TCO 1314Adapter cable for VDO Kienzle tachograph KTCO 1318, TVI 8400Adapter cable for VDO Kienzle tachograph FTCO 1319 TVI 2400Adapter cable for VDO Kienzle Tachograph MTCO 1324Adapter cable for Motometer tachograph EGK 100Earth terminal cable with clampPower supply 230 V / 50 Hz with 12 V DC charging voltageBoard power adapter 12/24 V DC 12 V DC charging voltagePlastic case

  • LCM Tester

    Model 27011 - Chroma ATE Inc.

    To meet the high accuracy and low price requirements for LCM Test device, Chroma 27011 that integrates the signal and power source provide a complete test solution for LCD Module. Its LVDS, TTL signal source fully complies with the digital signal standard, meanwhile with the 12V, 5V, 3.3V DC source output it is able to supply power to VDD, Backlight or LCM test without obtaining external power source.

Get Help